APPENDIX—15
(See REGULATION—8)

Qualifications of licensed technical Personnel for Preparation of schemes for Building Permit and supervision

1. The qualifications of the technical personnel and their competence to carry out different jobs for building permit and supervision for the purpose of licensing by the Authority shall be as hereinafter indicated.

ARCHITECTS

2. Qualification—The qualification for licensing Architect will be the Associate Membership of the Indian Institute of Architects or such Degree or Diploma which makes him eligible for such membership or qualification mentioned in Schedule-XIV of Architects Act, 1972 and registered with the Council of Architecture as provided by the provisions of the Architects Act, 1972.

2. (1) A licensed Architect shall be competent to carry out work related to building permit and shall be entitled to submit the following:

(i) All plans and related information connected with building permit.
(ii) Structural details and calculations for building on plots upto 500 sq. mtrs. and upto four storeys high, and
(iii) Certificate of supervision for all buildings.

ENGINEERS

3. (1) Qualifications—The qualifications for licensing of the engineers will be corporate Membership (Civil) of the Institution of Engineers or such degree/diploma in Civil Municipal or structural Engineering which makes him eligible for such membership or which is recognised by the Uttar Pradesh Public Service Commission for the post of an Assistant Engineer.

(2) A licensed engineer shall be competent to carry out the work related to building permit and shall be entitled to submit the followings:

(i) All plans and related information connected with building permit on plots upto 120 sq. mtrs. and upto two storeys.
(ii) Structural details and calculations for all buildings.
(iii) Certificate of supervision for all buildings.

DRAFTSMAN

4. Qualifications—(1) The qualification for licensing of the Draftsman will be:

(i) Three years Diploma in Architectural/Assistantship or Architectural Draftsmanship.
(ii) Draftsmanship in Civil Engineering from l.T.I. with five years experience under Architect/Engineer, from a recognised institution which would enable him for the post of senior Draftsman recognised by the Uttar Pradesh Public Service Commission.
(iii) Diploma in Civil Engineering with 2 years experience.

(2) A licensed draftsman shall be entitled to submit:

(i) All plans and related information for buildings permit on plots upto 75 sq. mtrs. and upto two storeys.
(ii) Certificate of supervision of buildings on plots upto 75 sq. mtrs. and upto two storeys.

GROUP OR AGENCY

5. When a group or agency comprising of qualified Architect/Engineer/draftsman is practising then the qualification and competence of work will be the combination of the individual qualification and competence given under paras 2, 3 and 4 above and the agency shall be licensed by the Authority.

TABLE NO.1
Per Capita Water requirements for Buildings

Serial No. Type of Building Consumption per head per day(in ltrs.)
1 2 3
1 Residential 135
2 Educational
(a) Day Schools
(b) Boarding Schools
45
135
3 Institutional (Medical)
(a) No. of beds not exceeding 100
(b) No. of beds exceeding 100
(c) Medical quarters and hostels
340
450
135
4 Assembly (per seat of accommodation) 15
5 Government of Semi-public business 45
6 Mercantile (Commercial)
(a) Restaurants (per seat) 70
(b) Hotels with lodging accommodation (per bed) 180
(c) Other business building 45
7 Industrial 45
8 Storage (including Warehousing) 30
9 Hazardous 30
10 Intermediate stations (excluding mail) and express stops
(a) Where bathing facilities are provided 45
(b) In the case of others 23
11 Junctions Stations:
(a) Where bathing facilities are provided 70
(b) In the case of others 45
12 Terminal Stations 45
13 International and Domestic Airports 70

Explanation—The number of persons for serial no. 10 and 13 shall be determined by the average number of passengers handled by the Station daily.

TABLE NO 2
Flushing Storage capacities

Serial No. Classification of Buildings Storage Capacity
1 For tenements having common convenience 900 litres net per WC seat.
2 For residential premises other than tenements having common conveniences. 270 litres net for one WC seat and 180 litres for each additional seat in the same flat.
3 For Factories and Workshops 900 litres per WC seat and 180 litres per urinal seat.
4 For cinemas public assembly halls or the like 900 litres per WC seat and 350 litres per urinal seat.

TABLE NO. 3
Domestic Storage capacities

Serial No. No. of floors Storage capacity Remarks
For premises occupied as tenements with common conveniences
1. For 1 (Ground floor) Nil Provided no downtaken fittings are installed.
2. For 2,3,4,5 and upper floors 500 litres per tenement ….
For premises occupied as flats or blocks
1. For 1 ground floor Nil Provided no downtaken fittings are installed.
2. For 2,3.4,5 and upper floors 500 litres per tenement ….

Explanations-.

  1. If the premises are situated at a place higher than the road level in front of the premises, storage at ground level shall be provided on the same lines as of floor.
  2. The above storage may be permitted to be installed provided that the total domestic storage calculated on the above basis is not less than the storage calculated on the number of down take fittings according to the scales given below-
    Downtake taps 70 liter each.
    Showers 13 litres each.
    Bath tubs 200 litres each.

TABLE NO. 4
Sanitation requirements for Hotels

Serial No. Fitments For residenitial public and staff For public rooms For non-residential staff
For males For females For males For females
1 2 3 4 5 6 7
1 Water closet One for 7 persons omitting occupants of the room with attached water closet, minimum of two if both sexes are lodged One per 100 persons upto 400 persons for over 400 and at the rate of one per 250 persons or part thereof Two for 100 upto 200 persons. Over 200 add or one per 100 persons or part thereof One for 1-15 persons. Two for 16-35 persons. Three for 36-65 persons. Four for 66-100 persons One for 1-12 persons. Two for 13-25 persons. Three for 26-40 persons. Four for 41-57 persons
2 Ablution Taps One in each water closet One in each water closet One in each water closet One in each water closet One in each water closet
One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinal.
3 Urinals …. One for 50 persons or part thereof Nil upto 6 persons. One for 7-20 persons. Two for 21-45 persons. Three for 46-70 persons. Four for 71-100 persons ….
4 Wash Basins One per 10 persons omitting the wash basins installed in room with bath suites One per water closet and urinal provided One per water closet provided One for 1-15 persons. Two for 16-35 persons. Three for 36-65 persons. Four for 66-100 persons One for 1-12 persons. Two for 13-25 persons. Three for 26-40 persons. Four for 41-57 persons
5 Baths One per 10 persons Omitting occupants of the room with bath in suites …. …. …. ….
6 Slope sinks One for 30 bedrooms (one per floor min.) …. …. …. ….
7 Kitchen sinks One in each kitchen One in each kitchen One in each kitchen One in each kitchen One in each kitchen

Explanation—It may be assumed the two thirds of the number are males and one third females.

TABLE NO 5
Sanitation requirements for Educational Buildings

Serial No. Fitments Nursery Schools Boarding institutions Other educational institutions
For Boys For Girls For Boys For Girls
1 Water closet One per 15 pupils or part thereof. One per every 8 pupils or part thereof. One per every 6 pupils or part thereof. One per 40 pupils or part thereof. One per 25 pupils or part thereof.
2 Ablution One in each water closet. One in each water closet. One in each water closet. One in each water closet. One in each water closet.
One water tap with draining arrangements will be provided for every 50 persons or part there of in the vicinity of water closet urinal.
3 Urinals …. One per every 20 pupils or part thereof. …. One per every 25 pupils or part thereof. ….
4 Wash basin One per 15 pupils or part there of. One per every 8 pupils or part there of. One for every 6 pupils or part there of. One for every 40 pupils or part there of. One per 40 pupils or part there of.
5 Baths One bath sink per 40 pupils. One for every 8 pupils or part there of. One for every 6 pupils or part there of. …. ….
6 Drinking water fountains. One for every 50 pupils or part there of. One for every 50 pupils or part there of. One for every 50 pupils or part there of. One for every 50 pupils or part there of. One for every 50 pupils or part there of.
7 Cleaners sinks …. One per floor minimum One per floor minimum One per floor minimum One per floor minimum

TABLE NO.6
Sanitation requirement for Institutional (Medical) Buildings (Hospitals).

Serial No. Fitments Hospitals with indoor patients wards Hospitals with outdoor patients wards Administrative Building
For males and females For males For females For male Personnel For female Personnel
1 2 3 4 5 6 7
1 Water closet One for every 8 beds or part thereof One for every 100 persons or part thereof Two for every 100 persons or part thereof One for every 25 persons or part thereof One for every 45 persons or part thereof
2 Ablution One in each water closet one water tap with draining arrange -ments in the vicinity of water closet and urinals for every 50 beds or part thereof One in each water closet One in each water closet One in each water closet One in each water closet
One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinal.
3 Wash basins Two upto 30 beds add for every additional 30 beds or part thereof One for every 10 persons or part thereof One for every 100 persons or part thereof One for every 25 persons or part thereof
4 Baths with shower One for every 8 beds One in each floor
5 Bed pan washing sinks One for each ward sinks
6 Cleanser sinks One for each ward One per floor minimum One per floor minimum
7 Kitchen sinks and dish washers (where kitchen is provided) One for each ward
8 Urinals One for every 50 persons or part thereof Nil upto 6 persons one for 7-20 persons Three for 46-70 persons Two for 21-45 persons. Four for 71-100 persons
From 101 to 200 persons add at the rate of 3 per cent for every 200 persons and at the rate of 2.5 per cent.

TABLE NO. 7
Sanitation requirements for Institution (Medical) Buildings (Staff Quarters and Hostels)

Serial No. Fitments Doctors Dormitories
    For male staff For female staff Nurses Hostel
1 Water closet One for four  persons One for four persons One for four persons or part thereof
2 Ablution taps One in each water closet One in each water closet One in each water closet
    One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinal.
3 Wash Basins One for every 8 persons or part thereof. One for every 8 persons or part thereof. One for every 8 persons or part thereof.
4 Bath with shower One for 4 persons or part thereof. One for 4 persons or part thereof. One for 8 persons or part thereof.
5 Cleaners sinks One per floor minimum One per floor minimum One per floor minimum

TABLE NO. 8
Sanitation requirements for Government or semi Public Business Buildings

Serial No. Fitments For male personnel For female personnel
1 2 3 4
1 Water closet One for every 25 persons or part thereof One for every 15 persons or part thereof
2 Ablution taps One in each water closet One in each water closet
    One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinal.
3 Urinals Nil upto 6 persons One for 7-20 persons
Two for 21-45 persons Three for 46-70 persons Four for 71-100 persons.
From 101 to 200 persons add at the rate of 3 per cent.
For every 200 persons add at the rate of 2.5 per cent.
 
4 Wash basins One for every 25 persons or part thereof One for every 25 persons or part thereof
5 One for every 100 persons with a minimum of one for each other. One for every 100 persons with a minimum of one for each other  
6 Baths One on each floor One on each floor
7 Cleanser Sinks One per floor minimum preferable in or adjacent to sanitary rooms One per floor minimum preferable in or adjacent to sanitary rooms

TABLE NO. 9
Sanitation requirements for Assembly Building (Theatres Auditoriums and cinemas)

Serial No.   For Public For staff
  Fitments Male Female Male Female
1 Water Closet One per 100 persons upto 400 persons
For over 400 persons add at the rate of one per 250 persons or part thereof
Two per 100 persons upto 200 persons
For over 200 persons add at the rate of one per 100 persons or part thereof
One for 1-15 persons Two for 16-35 persons One for 1-12 persons Two for 13-25 persons
2 Ablution taps One in each W.C. One in each W.C. One in each W.C. One in each W.C.
    One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
3 Urinals One for 50 persons part thereof   Nil upto 6 persons. One for 7-20 persons. Two for 21-45 persons  
4 Wash basins One for every 200 persons. One for every 200 persons or part thereof One for 1-15 persons Two for 16-35 persons One for 1-12 persons Two for 13-25 persons

Explanation - It may be assumed that two thirds of the number are males and one third femals.

TABLE NO. 10
Sanitation requirements for Assembly Building (Art Galleries Libraries and Museum)

Serial No.   For Public For Staff
  Fitments Male Female Male Female
1. Water closet One per 200 persons upto 400 persons for over 400 persons add at the rate of one per 100 persons or part thereof One per 100 persons upto 200 persons. One for 1-15 persons. Two for 15-35 persons One for 1-12 persons. Two for 13-25 persons.
2. Ablution taps One in each w.c. One in each w.c. One in each w.c. One in each w.c.
    One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
3. Urinals One for 50 persons   Nil upto 6 persons. One for 7-20 persons. Two for 21-45 persons.  
4. Wash Basins One for every 200 persons or part thereof. For over 400 persons add at the rate of one for 250 persons or part thereof. One for every 200 persons or part therof. For over 400 persons add at the rate of one for 250 persons or part thereof. One for 1-15 persons. Two for 16-35 persons. One for 1-12 persons. Two for 13-25 persons.
5. Cleaners Sinks One per floor minimum. One per floor minimum. One per floor minimum. One per floor minimum.

Explanation—It may be assumed that two thirds of the number are males and one third females.

TABLE NO. 11
Sanitation requirements for Assembly Buildings (Restaurants)

Serial No.   For Public For Staff
  Fitments For male For female For male For female
1 Water Closet One for 50 seats upto 200 seats. For over 200 seats add at the rate of one per 100 seats or part thereof One for 50 seats upto 200 seats. For over 200 seats add at the rate of one per 100 seats or part thereof One for 1-15 persons. Two for 16-35 persons. Three for 36-65 persons .Four for 66-100 persons One for 1-12 persons. Two for 13-25 persons. Three for 26-40 persons. Four for 41-57 persons. Five for 58-77 persons. Six for 78-100 persons
2 Ablution taps One in each w.c. One in each w.c. One in each w.c. One in each w.c.
  One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
3 Urinals One for 50 seats   Nil upto 6 persons. One for 7-20 persons. Two for 21-45 persons. Three for 46-70 persons. Four for 71-100 persons  
4 Wash Basins One for every water closet provided One for every water closet provided One for every water closet provided One for every water closet provided
5 Kitchen sinks and dish washers     One in each kitchen  
6 slop or service sinks     One in the restaurant  

Explanation—It may be assumed that two thirds of the number are males and one third females.

TABLE NO. 12
Sanitation requirements for Shops and Commercial Offices

Serial No. Fitments For personnel
1. Water Closet One for every 25 persons or part thereof exceeding 15 (including employers and customers).
For female personnel 1 per every 13 persons or part thereof exceeding 10.
2. Drinking Water Fountain One for every 100 persons with a minimum of one on each floor.
3. Wash Basin One for every 25 persons or part thereof.
4. Urinal Nil upto 6 persons. One for 7-20 persons two for 21-45 persons three for 46-70 persons. Four for 71-100 persons and from 101 to 200 persons add at the rate of 3 percent. For over 200 persons add the rate of 2.5 percent.
5. Cleaners, Sink One per floor minimum preferable in or adjacent to sanitary.

Explanation—Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. The male-female calculation a ratio of 1:1 may be assumed.

TABLE NO. 13
Sanitation Requirements for Residences

Serial No. Fitments Dwelling with individual conveniences Dwelling without individual conveniences
1. Bath room One provided with water tap One for every two tenements
2. Water closet One One for every two tenements
3. Sink (or Nahani) in the floor One  
4. Water tap One One with draining arrangement in each tenement.
One in common bath rooms and common water closets.

Explanation—Where only one water closet is provided in a dwelling the bath and water closet shall be separately accommodated.

TABLE. NO. 14
List of various deviations/additions/alteration which can be considered for regularisation/compounding in greater NOIDA Industrial Development Authority Complex.

Serial No. Item Rate proposed for Greater NOIDA Industrial Development Authority
1. (a) Unauthorised construction done before submitting the plans for sanction or unauthorised construction carried out after submission of building plan but, prior to issue of Sanction if permitted under approved building bye-laws. At the rate 5 percent of the cost of construction taking cost as Rs. 2,000.00 per sq. mtr.
(b) Unauthorised construction done after expiry of the sanction period and without setting the sanction revalidated or unauthorised construction done by persons other than the one in whose name sanction was previously obtained without obtaining fresh sanction in favour of successors or deviations against the sanctioned building plans, if permissible under approved Building Bye-Laws. 1 percent of the cost of construction taking construction as Rs 2,000.00 sq. mtr.
(c) Deviation against the sanctioned building plans within sanctioned covered area and without infringing any BBL/setback.

No penalty.

2. Excess coverage beyond permissible on each floor (i) 5 percent of the permissible coverage.
Beyond 5 percent and up to 10 percent.
Beyond 10 percent and upto 15 percent.
Rs. 2,000.00 (Rs. 5,000.00 in case of commercial) per sq. mtr.
Rs. 5,000.00 (Rs. 8,000.00 in case of commercial.)Not permissible.
3. (a) Excess area of loft
(i)Residential :
Upto 5 percent of the loft area allowed in approved Building bye-laws.
@ 10 percent cost of the cost of the construction taking  Construction cost as Rs. 150.00 per sq. mtr.
(ii) Beyond 5 percent and upto 10 percent of the loft area allowed in approved Building Bye-laws. @ 20 percent cost of the cost of the construction taking construction cost as Rs. 150.00 sq. mtr.
3. (b) Other Buildings :

Ditto.

(i) Upto 5 percent of the loft area allowed in Tentative Building Bye-laws of greater Noida Industrial Development Authority.
(ii) Beyond 5 percent and up to 10 percent of the loft area allowed in Tentative Building Bye-laws of the greater NOIDA Industrial Development Authority. @ 40 percent cost of the cost of the construction taking construction cost as Rs. 150.00 sq. mtr.
4. Setback infringement on each floor :
(i) Up to 0.15 mtr. Rs. 2,000.00 (Rs. 5000.00 in case of commercial) per sq. mtr. + excessive coverage if not charged otherwise.
(ii) Beyond 0.15 M and up to 0.30M Rs. 3000.00 (Rs. 8000.00 in case of commercial) + excessive coverage if not charged otherwise.
(iii) Beyond 0.30 M Not permitted.
5. Reduction of the height of W.C. bath, latrine, kitchen :
(i) Up to 0.07 M No penalty
(ii) Beyond 0.075 M and up to 0.30 M Rs. 25.00 per cms.
(iii) Beyond 0.30 M Not permitted.
6. Reduction in width of W.C. bath, latrines, kitchen and room provided the defect in area is not more than 20 percent of minimum permissible are :
Up to 0.075 M No penalty
Beyond 0.075 M and up to 1.15 M Rs. 1000.00 per sq. mtr.of excess area
7. Increase in the size of the canopy @ 25 percent of the cost of the construction of entire canopy taking construction cost as Rs. 150.00 per sq. mtr.
8. Few uncovered steps of the main staircase in the setback portion Rs. 100.00 per step.
9. Reduction in the headway staircase from the minimum permissible limits :
(i) Up to 0.075 M No penalty
(ii) Beyond 0.075 M and upto 0.015 M Rs. 50 per cm.
(iii) Beyond 0.015 M Not permitted.
10. Steps of staircase defective in tread and riser or in case of more than 12 riser in each flight. Rs. 50.00 each
11. Pargola if provided only for Architectural reasons and in case of residential building only. @ 25 percent of the cost of construction of the entire Pargola taking construction cost of Rs. 200.00 per sq. mtr.
12. Staircase with riser but without enclosed area below it and without mumty at top in rear setback As per covered area rate.
13. End wall above 0.45 M and upto 0.90 M width in terrace type construction. Rs 100.00 each
14. Enclosing of the front balcony or stair case by Jali-wall. @ as per covered rates @ infringement of setback @ Rs. 500.00 per sq. mtr. of the affected area of setback.
15. RCC projection beyond 0.75 M and upto 0.90 M and where on ones own land even if accessible. @ 10 percent of the cost of construction taking construction cost as Rs. 250.00 per sq. mtr.
16. Extra slab in mumty provided headway is maintained as per approved building byelaws only upto 0.90 M @ 25 percent of the cost of construction taking construction as Rs. 150.00 per sq. mtr.
17. Excess height of the building from point of view of rear airplane Rs. 1000.00 per sq. mtr. of the affected area.
18. Defective height of passage
(i) Upto 0.075 M No penalty
(ii) Beyond 0.075 M and up to 0.15 M Rs. 25.00 per cm.
(iii) Beyond 0.15 M Not permitted
19. Defective height of the mezzanine
(i) Upto 0.15 M Rs. 25.00 per cm.
(ii) Beyond 0.15 M upto 0.30 M Rs. 50.00 per cm.
20. Defective height of the Loft in residential building beyond 1.5 M permissible:
(i) Up to 0.15 M Rs 25.00 per cm.
(ii) Beyond 0.015 M and upto 0.30 M Rs. 50.00 per cm.
(iii) Beyond 0.30 M Not permitted
21. Defective Height of the loft in commercial building beyond 1.626 M (shop) :
(i) Up to 0.075 M @ Rs. 100.00 per sq. cm.
(ii) Beyond 0.075 M and upto 0.15 M @ Rs. 200.00 per sq. cm.
(iii) Beyond 0.15 M and upto 0.30 M @ Rs. 500.00 per sq. cm.
22. Defective height of basement :
(i) Up to 0.015 M @ Rs. 100.00 per sq. cm.
(ii) Beyond 0.015 M and upto 0.30 M @ Rs. 200.00 per sq. cm.
(iii) Beyond 0.30 M and upto 0.45 M @ Rs. 500.00 per sq. cm.
23. Partitioning of Barsati provided the area of Barsati floor does not exceed permissible coverage area./Rs. 500.00 lumpsum
24. (i) Balcony width up to 0.75 M No penalty
(i) Balcony width up to 0.90 M Rs. 100.00 per sq. mtr.
(i) Balcony width above 0.90 M Not permitted.
25. Partition walls in mezzanine floor and basement floor provided no byelaws are in fringed :
(i) Masonry 5 percent of the cost of construction taking construction cost as Rs. 200.00 cubic mtr.
(ii) Wooden up to 2 M height No penalty
(iii) Beyond 2 M height Rs. 200.00 per cubic mtr.
26. End wall up to 0.45 M as architectural feature No penalty
27. RCC Cup Board up to 0.60 M width in setback from ground level. Rs. 2,000.00 per sq. mtr.
28. (i) Bay window up to 0.60 M width in setback Rs. 2,000.00 per sq. mtr.
(ii) Beyond 0.60 M (Bay window) Not permitted
29. Boiler with flue bhatties, Electric furnace and the like if uncovered in the rear setback of built-up shed constructed by the Authority and rear and side setback in case of industrial plot (a) Rs. 1,500.00 per sq. mtr. up to 10 sq. mtr.
(b) Rs. 3,000.00 per sq. mtr. next 10 sq. mtr.
(c) Above 20 sq. mtr. not allowed
30. Cooling tower in the rear setback of built-up shed constructed by authority and rear and side setback in case of industrial plot Rs. 500.00 per sq. mtr.
31. Electric transformer in the rear setback of built-up shed constructed by Authority, if there is no setback then in the front back and rear or side-back in case of industrial plot. (a) Rs. 200.00 up to 100 KVA.
(b) Rs. 300.00 above 100 KVA.
32. Industrial vessels without any cover thereupon in the rear or front setback of built-up shed constructed by the Authority and front rear or side set-back in case of industrial plot. No penalty
33. Tank and Hodies in the rear or front setback of built-up shed constructed by the Authority and front rear or side setback in case of industrial plot. No penalty
34. Cycle/scooter stand even if covered/temporary cover in the rear or front setback of built-up shed constructed by authority and front rear or side setback in case of industrial plot. No penalty
 
 
  

Plot Holders / Allotees can obtain details of their up-to-date account status from our specially constructed web site.  Please click here to browse to the web site

  