Appendix- 8(A)

Kindly tick the relevant codes that have been followed.

STRUCTURAL SAFETY AND NATURAL HAZARD PROTECTION OF BUILDINGS

Requirements specified in the following Indian Standards, Codes and guidelines and other documents needs to be observed for structural safety and natural hazard protection of buildings etc:-

a) For General Structural Safety
   
 

1)  IS : 1905 � 1987 �Code of practice for structural safety of buildings; masonry walls� Indian Standards Institution, March 1981

2)  IS : 1904 � 1978 �Code of practice for structural safety of buildings; foundation� Indian Standards Institution

3)  IS : 456 - 2000 �Code of practice for plain and Reinforced Concrete� Indian Standards Institution, September 2000.

4)  IS : 800 - 1984 �Code of practice for general construction in steel� Indian Standards Institution, February 1985

5) IS : 883 - 1966 �Code of practice for design of structural timbers in buildings; � Indian Standards Institution, March 1967

 
 
 
 
  Besides any other relevant Indian Standards will need to be referred to
   
b) For Earthquake protection
   
 

1)  IS : 1893 � 1984 �Criteria for Earthquake resistant Design of Structures (Fourth Revision)� June 1986

2)  IS : 13920 � 1993 �Ductile detailing of reinforced concrete structures subjected to Seismic forces � Code of Practice�  November 1993

3)  IS : 4326 � 1993 �Earthquake Resistant Design and Construction of Buildings � Code of Practice (Second Revision)�  October 1993

4)  IS : 13828 � 1993 �Improving Earthquake Resistance of Low Strength Masonry Buildings - Guidelines� August 1993.

5)  IS : 13827 � 1993 �Improving Earthquake Resistance of Earthen Building Guidelines� October 1993

6)  IS : 13935 � 1993 �Repair and Seismic Strengthening of Buildings � Guidelines� November 1993.

7)  �Improving Earthquake Resistance of Building � Guidelines� by expert group, Government of India, Ministry of  Urban Affairs and Employment, published by BMTPC 1998.

8)  The National Building Code of India 1983

For location of the building in hazard prone area of earthquakes, cyclone or wind storms and floods, reference may be made to the following:

�Vulnerability Atlas of India� by expert group, Government of India, Ministry of Urban Affairs and Employment, published by BMTPC 1997.

 
 
 
 
 
 
 
 
 
   
   

NOTE :

1.   As and when anyone of the above referred standards and documents is revised, the design and construction of Buildings thereafter must satisfy the latest version for approval of building plans by the Authority.

The above information is factually correct.

Signature of owner with date                               Signature of the Engineer who had/will

Supervised the construction ( with   qualification and experience as mentioned in Appendix 12)

Name (Block) ����������.                 Name (Block) �������Address:

                     ����������.                 Legible Seal:

                                                                        (with address)

 

Signature of the Licensed Technical Person who had/will

Supervised the construction

 

Name (Block) ��������.

Registration No. ����..

Legible Seal : ��������..

With address


--------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Appendix �8 (B)

BUILDING INFORMATION SCHEDULE

1. Building Address Plot No. Scheme/Colony Town District
2. Building function & Locations  
  2.1 Use Institutional  Commercial Industrial *
  2.2 Importance Ordinary Important Hazardous * IS:1893
  2.3 Seismic Zone V(IX)  IV(VIII)  III(VII) II(VI) IS:1893
    (Design Intensity Used)          
3. Design EQ Factor a0=�� I=�� b ah=�� IS:1893
 
  1. Foundation
         
4.1 Soil type at site (Note 2) Rock/stiff Medium # Soft  Liquefiable Expensive(B.C.)  IS:1904
4.2 Type of Foundation Strip Indiv.Col. Fittings/Raft Bearing Piles Friction Piles IS:1893
5. Load Bearing Wall Buildings          
  5.1 Building Category A(ah<.05) B(ah=.05 to .06) C(ah.06 to<.08) D(ah.08 to a <9.12) E(ah>0.12) IS:4326
  5.2  Bearing Walls Brick Stone Solid Block Hollow Block   Abode
  5.3 Mortar (Note 4) C : S=1:�. C:L:S=1 �.. L:S=1: � Clay Mud *
   5.4 Floors R.C. slabs Stone slabs on joists Prefab flooring elements   *  
  5.5  Roof structure  Flat like floors/pitched Trussed/Raftered/A Frame/Slopping R.C. Slab    
  5.6 Roof covering  CGI Sheeting   AC Sheeting Clay tiles/Slate Wood shingle *
  5.7  Opening in walls Control used on sizes? Control used on location? Strengthening around? IS:4326  
      Yes/No/NA  Yes/No/NA  Yes/No/NA   IS:13828  
  5.8 Bands Provided Plinth Band Lintel Band Roof/Eave Band Gable Band Ridge Band -do-

 

  5.9 Vertical Bars   At corners of rooms  At jambs of openings   -do-  
  5.10 Stiffening of Prefab R.C. screed & Band Floors/Roofs Peripheral band and connectors Diagonal planks and  all-round band IS:4326
6. Steel/R.C. frame buildings.              
  6.1   Building shape Both axes near symmetrical One axis near symmetrical/Unsymmetrical (torsion considered)
  6.2 Infills/partitions Out of plane stability check? Yes/No  In Plane stiffness considered? Yes/No IS:1893,IS:4326
  6.3 Ductile Detailing of  Beams? Columns? Beam/column Joint? Sheer Walls?  IS:13920
    RC Frames Yes/No Yes/No Yes/No Yes/No
  6.4 Ductile Detailing of  Beams? Columns? Beam/column Joint? SP6(6)  
    Steel Frames Yes/No Yes/No Yes/No  
 

                     

Notes

1.  Encircle the applicable Data point or insert information.

2.  Stiff.N>30:Medium.N=10.3:Soft.N<10:Liquefiable,poorly graded sands with N<15 under Water Table (see Note 5 of Table 1 in IS:1893)

Where N: Standard Penetration (I:2131 � 1981)

3. * Means my other. Specify.

C = Cement, S=Sand, L= Lime

The above information is factually correct.

  

Signature of owner with date   Signature of the Engineer who had/will
  Supervised the construction ( with   qualification and experience as mentioned in Appendix 12)
Name (Block) ����������.  Name (Block) �������........
����������.  Address: ..........................................
  Legible Seal:
  (with address)

  Signature of the Licensed Technical Person who had/will

Supervised the construction

Name (Block) ��������.

Registration No. ����..

Legible Seal : ��������..

With address

                                 

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 Appendix - 8(C)

CERTIFICATE

(The certificate to be submitted with the application for building permission along with the building drawings and Building Information Schedule)

1.  Certified that the building plans submitted for approval also satisfy the safety requirements as stipulated in the Indian Standard, Codes, guidelines and documents specified in the Appendix 8A regarding earthquake safety awareness and the information given in the attached Building Information Schedule is factually correct to the best of my knowledge and understanding.

2.  It is also certified that the structural design including safety from natural hazards including Earth Quake has been prepared by duly qualified Civil Engineer along with   qualification and experience as mentioned in Appendix 12.

3.  Location /Address of Building

            Plot No. ____________________

Scheme/Colony _______________

Town _______________________

District ________________________

4.  Particulars of Building

1.       Ground Coverage (sq mt)

2.       Total covered area (sq mt)

3.       Maximum Numbers of Floors above ground.

Signature of owner with date   Signature of the Engineer who had/will
  Supervised the construction ( with   qualification and experience as mentioned in Appendix 12)
Name (Block) ����������.  Name (Block) �������........
����������...................... Address: ..........................................
  Legible Seal:
  (with address)

Signature of the Licensed Technical Person who had/will

Supervised the construction

Name (Block) ��������.

Registration No. �������.

Legible Seal : ��������..

With address���������


--------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Appendix 8D

 
CERTIFICATE

(To be submitted with the application for obtaining completion certificate)

1.   Certified that the building plan for which completion plan has been submitted for approval conforms to the requirements of relevant Indian Standard Codes and National Building Code as referred in Appendix 8-A in respect of Structural Safety in general and National hazards including earthquake in particular.

2.   It is also certified that the building has been constructed as per approved foundation and structural designs provided by the Structural Engineer where are certified to be based on relevant Indian Standard Code and National Building Code as referred above and the building is safe for occupancy.

3.  Location /Address of Building

Plot No. ____________________

Scheme/Colony _______________

Town _______________________

District ________________________

4.  Particulars of Building

1.   Ground Coverage (sq mt)

2.   Total covered area (sq mt)

3.   Maximum Numbers of Floors above ground.

Signature of owner with date   Signature of the Engineer who had/will
  Supervised the construction ( with   qualification and experience as mentioned in Appendix 12)
Name (Block) ����������.  Name (Block) �������........
����������.  Address: ..........................................
  Legible Seal:
  (with address)

Signature of the Licensed Technical Person who had

Supervised the construction

Name (Block) ��������.

Registration No. ����..

Legible Seal : ��������..

With address