| INDUSTRIAL
BUILDINGS |
|
| (a) General setbacks in case of industrial building shall be as given in
the table below |
| Serial No. |
Plot size in sq.
mtrs. |
Front in mtrs. |
Rear in mtrs. |
Side in Mtrs. |
Side in mtrs. |
| 1 |
Up to 100 |
3.0 |
- |
- |
- |
| 2 |
From 101 to 450 |
4.5 |
1.5 |
3.0 |
1.5 |
| 3 |
From 451 t0 2,000 |
6.0 |
4.0 |
3.0 |
4.5 |
| 4 |
From 2,001 to 5,000 |
9.0 |
9.0 |
4.5 |
4.5 |
| 5 |
From 5,001 to 12,000 |
9.0 |
9.0 |
4.5 |
6.0 |
| 6 |
From 12,001 to 20,000 |
12.0 |
12.0 |
9.0 |
9.0 |
| 7 |
Above 20,000 |
15.0 |
15.0 |
15.0 |
15.0 |
|
| Note - Setbacks mentioned above are subject to
confirmation from the set backs plan prepared by the Authority. |
|
| (b) FAR - In case
of industrial building maximum FAR shall be as given in the table below |
| Serial
no. |
Plot
size in sq.mtrs. |
Maximum
Ground Coverage (%) |
Maximum
FAR |
| 1 |
Up to 100 |
60 |
120 |
| 2 |
from 101 to 450 |
60 |
100 |
| 3 |
From 451 to 2,000 |
55 |
80 |
| 4 |
From 2,001 to
12,000 |
55 |
70 |
| 5 |
From 12,001 to
20,000 |
50 |
65 |
| 6 |
Above 20,000 |
50 |
60 |
|
|
| Note:
Detailed Building Bye Laws and urban design regulations can be obtained from the office of
G.M. (Industries). |
|
|