|
Building Byelaws - Chapter V |
|
|
|
|
CHAPTER - V
For
Construction of Farm House Buildings in Agricultural Use Zone:-
34. Minimum
size of plot -
Minimum size of a
plot for farm house shall not be less than 0.5 hectares.
35. Maximum
coverage and FAR
|
(a) |
Maximum
permissible ground coverage for all types of activities |
10% |
|
(b) |
Maximum
permissible FAR |
20% |
|
(c) |
Residential
accommodation of watch and ward/maintenance staff |
15% of FAR |
|
(d) |
Maximum height |
10.0meters |
|
(e) |
Set backs |
Front
/abutting road-15.0 meter
All other
sides- 9.0 meter |
36. OTHER
PROVISIONS -
a) The maximum
permissible floor area includes the area of mezzanine floor also.
b) The height of
boundary wall shall be as specified in the Directions
c) Running
creeper or flowering creeper will be planted all along the wall.
d) Minimum 50%
of the total area of the farm house shall be under plantation/cultivation. At
least 100 trees per hectares have to be planted out of which at least 50%
shall be evergreen trees.
37. WATER
SUPPLY, SEWERAGE AND DRAINAGE:-
a) In case of
a plot for a farm house having dwelling units the owner thereof shall be
responsible to make lawful arrangements for potable water in the farm house.
b) The owner
shall be responsible to provide drains in the farms house to be used for rain
water and in case of dairy farm open or closed sanitary drains to clean sheds,
as may be required by the Authority.
c) The owner
shall be responsible to provide septic tank with necessary dispersion trenches
for disposal of human and animal wastes in the farm house within his own
premises.
d) The
dispersion trenches of the septic tank shall be 15 meters away from the
boundaries of the farm house.
38.
ELECTRIFICATION:-
The owner of a
farm house shall obtain electric connection directly from the appropriate
authority responsible for distribution on such terms and conditions and at his
own cost as decided by the appropriate authority.
Table no 2
Set backs for
all buildings other than buildings on residential plots
|
S.N. |
Plot size |
Front(in mts.) |
Rear(in mts.) |
Side(1)in
Mts. |
Side (2)(in
mts.) |
|
1 |
Up to 150 |
3.0 |
1.5 |
0 |
0 |
|
2 |
Above 150 to
up to 300 |
3.0 |
3.0 |
0 |
0 |
|
3 |
Above 300 up
to 500 |
4.5 |
3.0 |
3.0 |
0 |
|
4 |
Above 500 up
to 2000 |
6.0 |
3.0 |
3.0 |
3.0 |
|
5 |
Above 2000 up
to 4000 |
9.0 |
6.0 |
6.0 |
6.0 |
|
6 |
Above 4000 up
to 10000 |
15.0 |
6.0 |
6.0 |
6.0 |
|
7 |
Above 10,000
up to 20,000 |
15.0 |
9.0 |
9.0 |
9.0 |
|
8 |
Above 20,000
up to 40,000 |
20.0 |
9.0 |
9.0 |
9.o |
|
9 |
Above 40,000
up to 10,00,00 |
25 |
9.0 |
9.0 |
9.0 |
Notes:- (1)
Specific set backs shall be as per zonal plan prepared by the Authority when
ever such a plan has prepared by the Authority.
(1) In case the
permissible coverage is not achieved within setbacks, the setbacks of the
preceding category may be followed.
Table no 3
Features
permitted in the setbacks of the plots
|
S.N. |
Features |
Description |
|
1 |
DECORATIVE
COLUMN |
Columns purely
decorative and not load bearing shall be permitted in setback. Such
columns of any material and any number shall be permitted but maximum size
of each column shall not exceed 300mmX 300mm. |
|
2 |
BUTTRESSES: |
Buttresses,
any number, shall be permitted in setback up to maximum width of 750mm in
setback |
|
3 |
MOULDING AND
CORNICES, & MURALS: |
Murals,
moulding and cornices if provided along/ under any projection shall be
permitted upto a maximum width 150mm over and above the maximum
permissible dimensions of a projection or a canopy.
|
|
4 |
PLANTERS & SUN
CONTROL DEVICES:
|
Projection in
form of planter, cantilevered fins, egg crates and other sun control
devices shall be permitted in setback upto maximum width of 750 mm.
Maximum depths of such planters shall not exceed 600mm.
|
|
5 |
JALI: |
Jali of any
material shall be permitted over projections which are primarily meant to
cover window AC units and dessert cooler. Maximum width of such jailies
shall not be more than 75mm.
|
|
6 |
CASING /
ENCLOSURE TO COVER RAIN WATER PIPE |
Casing /
enclosure to cover rain water pipe of any material shall be permitted in
setback up to depth of maximum 250mm and maximum width of 600 mm may be
permitted. |
Table 4: Area
under canopy on building other than individual residential
|
S.N. |
Plot size |
Max Area
under Canopy |
|
1 |
Up to 150 |
Nil |
|
2 |
Above 150 to
up to 300 |
12 sqm (only
in side setback) |
|
3 |
Above 300 up
to 500 |
25 sq m |
|
4 |
Above 500 up
to 2000 |
40 sqm |
|
5 |
Above 2000 up
to 4000 |
55sqm |
|
6 |
Above 4000 up
to 10000 |
70 sqm |
|
7 |
Above 10,000
up to 20,000 |
85sqm |
|
8 |
Above 20,000
up to 40,000 |
100 sqm |
|
9 |
Above 40,000
up to 10,00,00 |
115 sqm |
Note : Min
width/radius of canopy shall be 1.8 m
|